Building Wire

You are here HomeProduct Power Infrastructure Building Wire
   
 

Annealed Copper Conductor:
Soft drawn bare annealed solid and stranded copper conductor
Application: For general purpose equipment and circuit grounding application

TTFN Type:
PVC Insulation, Nylon Jacket, 600 Volts, 90°C
Application: For power distribution from service entrance and feeders to branch circuits.

THW Type:
PVC Insulation, 600 Volts, 75°C
Application: For general purpose wiring in residential, commercial and industrial installations.

THHN / THWN Type:
PVC Insulation and Nylon Jacket, 600 Volts, 90°C Dry, 75°C Wet
Application: For power distribution in commercial and industrial projects.

XHHW-2 Type:
XLPE Insulation, 600 Volts, 90°C Wet or Dry
Application: XLPE insulated XHHW-2 is well suited for building wire for power distribution. It offers excellent dielectric, tensile strength and cut resistance properties.

USE-2 / RHH / RHW-2 Type:
XLPE Insulation, 600 Volts, 90°C Wet or Dry
Application: Ideal wiring solution for underground service entrance. It offers excellent dielectric, tensile strength and cut resistance properties.

URD, Duplex Type:
XLPE Insulation, 600 Volts, 90°C
Application: The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Duplex cable is designed for application as a secondary in two-wire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. For underground distribution from power supply source to the service entrance equipment of the building.

URD, Triplex Type:
XLPE Insulation, 600 Volts, 90°C
Application: Triplex cable is designed for application as a secondary in three-wire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. For underground distribution from power supply source to the service entrance equipment of the building.

URD, Quadruplex Type:
XLPE Insulation, 600 Volts, 90°C
Application: Quadruplex cable is designed for application as a secondary in three-phase, four-wire, underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. For underground distribution from power supply source to the service entrance equipment of the building.

TC Control Cable Type:
TFFN, THWN or THHN Conductors, PVC Jacket, 600 Volts, 90°C
Application: For industrial control, lighting and signal circuits where small diameter, flame retardant cables are required. Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire.

TC Power Cable Type:
THHN-THWN/PVC with Ground, 600 Volts, 90°C
Application: Industrial power to motors and other electrical devices. Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire.

XHHW-2/PVC with Ground, 600 Volts, 90°C Wet or Dry
Application: Industrial power to motors and other electrical devices. Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire in wet or dry conditions.


 